Por favor utiliza este link para citar o compartir este documento: http://repositoriodigital.academica.mx/jspui/handle/987654321/106593
Título: A study of elemental contents in atmospheric aerosols in Mexico City
A study of elemental contents in atmospheric aerosols in México City
Autores: 
Palabras clave: 
Fecha de publicación: 4-Oct-2012
Editorial: Centro de Ciencias de la Atmósfera
Descripción: Samples of airborne particulate matter with sizes between 0 and 15 µm in Mexico City were analyzed in order to evaluate its elemental composition. Samples were collected during one week in August 1990, using a Stacking Filter Unit (SFU), resulting in the separation between particles having sizes 2.5 to 15 µm (coarse), and smaller than 2.5 µm (fine). The collection period was from 6:00 to 12:00 hrs. Analyses with proton Induced X-ray Emission (PIXE) allowed the quantification of elements with atomic number greater than 10; Proton Elastic Scattering Analysis (PESA) gave information on hydrogen contents; and elemental carbon (soot) was measured by means of the Laser Integrating Plate Method (LIPM). Also, the gravimetric mass of the deposited matter was measured. The results permit then the possible identification of sources of the measured elements, with the help of Cluster Analysis. Moreover, the comparison of the gravimetric mass with the mass reconstructed from the elemental analysis supports the values obtained in the latter.
SE ANALIZARON MUESTRAS DE PARTÍCULAS SUSPENDIDAS EN EL AIRE CON TAMAÑOS COMPRENDIDOS ENTRE 0 Y 15 EN LA CIUDAD DE MÉXICO PARA EVALUAR SU COMPOSICIÓN ELEMENTAL. LAS MUESTRAS SE COLECTARON DURANTE UNA SEMANA, EN AGOSTO DE 1990, USANDO UNA UNIDAD DE FILTROS APILADOS (STACKING FILTER UNIT O SFU), MEDIANTE LA CUAL SE SEPARAN PARTÍCULAS CON TAMAÑOS DE 2.5 A 15 (GRUESAS) Y MENORES QUE 2.5 (FINAS). EL PERIODO DE COLECCIÓN FUE DE 6:00 A 12:00 HRS. EL ANÁLISIS CON EMISIÓN DE RAYOS X INDUCIDA POR PROTONES (PIXE) PERMITIÓ LA CUANTIFICACIÓN DE ELEMENTOS CONTENIDO DE HIDROGENO; MIENTRAS QUE EL CARBÓN ELEMENTAL (HOLLIN) SE MIDIÓ CON EL MÉTODO DE PLACA INTEGRADORA DE LÁSER (LIPM). ADEMÁS, SE MIDIÓ LA MASA GRAVIMÉTRICA DE LAS PARTÍCULAS DEPOSITADAS EN LOS FILTROS. LOS RESULTADOS OFRECEN LA POSIBILIDAD DE IDENTIFICAR LAS FUENTES DE LOS ELEMENTOS MEDIDOS, A TRAVÉS DE ANÁLISIS DE CÚMULOS. LA COMPARACIÓN ENTRE LA MASA GRAVIMÉTRICA Y LA MASA RECONSTRUIDA A PARTIR DEL ANÁLISIS ELEMENTAL REAFIRMO LOS VALORES OBTENIDOS PARA ESTE ULTIMO.
Other Identifiers: http://revistas.unam.mx/index.php/atm/article/view/8328
Aparece en las Colecciones:Atmosfera

Archivos de este documento:
No hay archivos asociados a este documento.